| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Voltage - Rated | Size / Dimension | Width | Air Flow | Static Pressure | Bearing Type | Fan Type | Features | Noise | Power (Watts) | RPM | Termination | Ingress Protection | Operating Temperature | Approval Agency | Weight |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
F280A3-113-D0520FAN IMP MTRZD 280X128.7MM 24VDC |
2,233 |
|
Datasheet |
F280 | Bulk | Active | 24VDC | Round - 280mm Dia | 128.7mm | 1166.0 CFM (32.65m³/min) | 1.913 in H2O (476.5 Pa) | Ball | Motorized Impellers | PWM Control, Speed Sensor (Tach) | 77.0dB(A) | 175.2 W | 2150 RPM | 4 Wire Leads | - | -22 ~ 158°F (-30 ~ 70°C) | - | 4.6 lbs (2.1 kg) |
|
G1G108-AB17-02FAN BLOWER 159X115.0MM 24VDC |
1,949 |
|
Datasheet |
G1G108 | Bulk | Active | 24VDC | Rectangular/Rounded - 159mm L x 185mm H | 115.0mm | - | - | Ball | Blower | PWM Control, Speed Sensor (Tach) | - | 42 W | 3000 RPM | 4 Wire Leads with Splice Terminals | IP22 | -13 ~ 140°F (-25 ~ 60°C) | CSA, EAC, UL | - |
|
|
9TP24P0H001FAN IMP MTRZD 221X71MM 24VDC |
1,862 |
|
Datasheet |
San Ace C221 | Box | Active | 24VDC | Round - 221mm Dia | 71.00mm | 622.0 CFM (17.42m³/min) | 2.130 in H2O (530.6 Pa) | Ball | Motorized Impellers | PWM Control, Speed Sensor (Tach) | 71.0dB(A) | 76.8 W | 3050 RPM | 4 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 2.4 lbs (1.1 kg) |
|
|
9TS48P0H001FAN IMP MTRZD 225X99MM 48VDC |
4,478 |
|
Datasheet |
San Ace C225 | Box | Active | 48VDC | Round - 225mm Dia | 99.00mm | 802.0 CFM (22.46m³/min) | 2.370 in H2O (590.0 Pa) | Ball | Motorized Impellers | PWM Control, Speed Sensor (Tach) | 70.5dB(A) | 99.8 W | 2900 RPM | 4 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 2.6 lbs (1.2 kg) |
|
9W2TS48P0S001FAN IMP MTRZD 225X99MM 48VDC |
4,474 |
|
Datasheet |
San Ace 225W | Box | Active | 48VDC | Round - 225mm Dia | 99.00mm | 830.0 CFM (23.24m³/min) | 2.550 in H2O (635.2 Pa) | Ball | Motorized Impellers | PWM Control, Speed Sensor (Tach) | 72.0dB(A) | 117.6 W | 3000 RPM | 4 Wire Leads | IP56 - Dust Protected, Water Resistant | -13 ~ 158°F (-25 ~ 70°C) | cURus, TUV | 3.3 lbs (1.5 kg) |
|
9B1TP48P0H001FAN BLOWER CF 270X99MM 48VDC |
4,215 |
|
Datasheet |
San Ace C221 | Box | Active | 48VDC | Square - 270mm L x 270mm H | 99.00mm | 622.0 CFM (17.42m³/min) | 2.130 in H2O (530.6 Pa) | Ball | Blower, Centrifugal | Locked Rotor Protection, PWM Control, Speed Sensor (Tach) | 71.0dB(A) | 76.8 W | 3050 RPM | 4 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 3.8 lbs (1.7 kg) |
|
9B1TP48P0G001FAN BLOWER CF 270X99MM 48VDC |
2,357 |
|
Datasheet |
San Ace C221 | Box | Active | 48VDC | Square - 270mm L x 270mm H | 99.00mm | 742.0 CFM (20.78m³/min) | 3.052 in H2O (760.0 Pa) | Ball | Blower, Centrifugal | Locked Rotor Protection, PWM Control, Speed Sensor (Tach) | 74.0dB(A) | 132 W | 3650 RPM | 4 Wire Leads | - | -4 ~ 140°F (-20 ~ 60°C) | CSA, TUV, UL | 3.8 lbs (1.7 kg) |
|
9B1TS48P0H001FAN BLOWER CF 270X119.0MM 48VDC |
1,212 |
|
Datasheet |
San Ace C225 | Box | Active | 48VDC | Square - 270mm L x 270mm H | 119.0mm | 802.0 CFM (22.46m³/min) | 2.370 in H2O (590.0 Pa) | Ball | Blower, Centrifugal | Locked Rotor Protection, PWM Control, Speed Sensor (Tach) | 70.5dB(A) | 99.8 W | 2900 RPM | 4 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 4.2 lbs (1.9 kg) |
|
R1G225-AF11-14FAN IMP MTRZD 225X107.0MM 48VDC |
4,415 |
|
Datasheet |
R1G225 | Bulk | Active | 48VDC | Round - 225mm Dia | 107.0mm | - | - | Ball | Motorized Impellers | Locked Rotor Protection, PWM Control, Speed Sensor (Tach) | - | 95 W | 2700 RPM | 4 Position Rectangular Connector | IP44 | -13 ~ 140°F (-25 ~ 60°C) | CSA, UL | - |
|
W1G250-HH37-52FAN AXIAL 280X80MM BALL 24VDC |
4,489 |
|
Datasheet |
W1G250 | Bulk | Active | 24VDC | Square - 280mm L x 280mm H | 80.00mm | - | 0.562 in H2O (140.0 Pa) | Ball | Tubeaxial | Locked Rotor Protection, PWM Control, Speed Sensor (Tach) | - | 105 W | 2750 RPM | Terminal Block | IP42 | -13 ~ 140°F (-25 ~ 60°C) | CSA, EAC, UL | - |
|
9W2TP24P0H001FAN IMP MTRZD 221X71MM 24VDC |
1,347 |
|
Datasheet |
San Ace 221W | Box | Active | 24VDC | Round - 221mm Dia | 71.00mm | 622.0 CFM (17.42m³/min) | 2.130 in H2O (530.6 Pa) | Ball | Motorized Impellers | PWM Control, Speed Sensor (Tach) | 71.5dB(A) | 80.4 W | 3050 RPM | 4 Wire Leads | IP56 - Dust Protected, Water Resistant | -13 ~ 158°F (-25 ~ 70°C) | cURus, TUV | 2.6 lbs (1.2 kg) |
|
D1G146-AA33-52FAN BLOWER CF 205X232.0MM 48VDC |
2,699 |
|
Datasheet |
D1G146 | Bulk | Active | 48VDC | Rectangular/Rounded - 205mm L x 219mm H | 232.0mm | - | - | Ball | Blower, Centrifugal | Locked Rotor Protection, PWM Control, Speed Sensor (Tach) | 61.0dB(A) | 105 W | 1350 RPM | 4 Wire Leads | IP42 | -13 ~ 140°F (-25 ~ 60°C) | CSA, EAC, UL | - |
|
9TP48P0H001FAN IMP MTRZD 221X71MM 48VDC |
2,489 |
|
Datasheet |
San Ace C221 | Box | Active | 48VDC | Round - 221mm Dia | 71.00mm | 622.0 CFM (17.42m³/min) | 2.130 in H2O (530.6 Pa) | Ball | Motorized Impellers | PWM Control, Speed Sensor (Tach) | 71.0dB(A) | 76.8 W | 3050 RPM | 4 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 2.4 lbs (1.1 kg) |
|
|
5152HQ/MF75090V1-C330-S9ADC BLOWER 80X87X11MM TACH/PWM |
3,976 |
|
Datasheet |
- | Box | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
|
5151HQ/MF75090V1-C331-S9ADC BLOWER 80X87X11MM TACH/PWM |
100 |
|
Datasheet |
- | Box | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
|
5142HQ/EE92251B1-000C-G99DC FAN 92X25MM TACH |
2,474 |
|
Datasheet |
- | Box | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
|
5145HQ/MF30101V2-1Q03A-G9DDC FAN 30X10MM TACH |
1,420 |
|
Datasheet |
- | Box | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
|
5148HQ/MG75080V1-1C011-S9ADC BLOWER 74X76X8MM TACH/PWM |
4,537 |
|
Datasheet |
MG | Box | Active | 5VDC | Rectangular/Rounded - 76mm L x 74mm H | 7.50mm | 5.8 CFM (0.163m³/min) | 0.951 in H2O (236.9 Pa) | Sleeve | Tubeaxial | Auto Restart, PWM Control, Speed Sensor (Tach) | 49.0dB(A) | 2 W | 4900 RPM | 4 Position Rectangular Connector | - | 14 ~ 158°F (-10 ~ 70°C) | CE, CSA, TUV, UR | - |
|
|
5155HQ/EG50060S1-C440-S9ADC BLOWER 93X95X7.5MM TACH/PWM |
1,797 |
|
Datasheet |
EG | Box | Active | 5VDC | Rectangular/Rounded - 96.95mm L x 79.1mm H | 10.10mm | 6.5 CFM (0.182m³/min) | 0.430 in H2O (107.1 Pa) | Sleeve | Blower | Auto Restart, PWM Control, Speed Sensor (Tach) | 40.8dB(A) | 2 W | 4300 RPM | 4 Position Rectangular Connector | - | 14 ~ 158°F (-10 ~ 70°C) | CE, CSA, TUV, UR | - |
|
CHA6012BH-15D12V 0.17A 60*15 BALL 2; 22.39CFM |
3,009 |
|
- |
- | Box | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |